Analysis of 6 main failure causes of micro pump
First: when starting the motor does not rotate when the micro pump.
Reason:
1 auxiliary switch DC regulated power supply fault;
2 battery or
battery without power is not enough;
3 line contact;
4 motor and carbon
brush contact; Second: after the start of the pump motor work but not
the water.
Reason:
1 there are debris or particulate impurities in the
pump;
2 suction process is higher than the pump rated suction process;
Third: traffic shortage. Reason: 1 the actual head of the pump more than
the allowable lift; 2 voltage is too low, the motor speed is slow;
3
suction process is too high;
4 air entry into the pipe; Fourth: the flow
gradually become small.
Reason:
1 water inlet impurities blocked;
2
filter use time is too long, there is a particle impurity; Fifth: the
work of the micro pump water abnormal interrupt.
Reason:
1 motor does
not start, the exclusion of circuit fault;
2 pipe plug, remove plug;
3
pipeline rupture, repair welding or replacement;
4 strainer plug, plug
removal;
5 water outlet pipe exposed surface; Sixth: the pump is running
at the time of violent vibration or noise abnormal increase.
Reason:
1
access voltage higher than the set voltage;
2 mounting angle is not
fixed;
3 motor or pump shaft bending.